  Datasheet File OCR Text:
  memory hicorder recorders 8870 -20 hioki's traditional memory hicorder functions are now condensed into a low- profile, turn-key device. the compact design includes a beautiful wide-screen qvga-tft lcd. easy to use, with great functionality and performance, you will want to keep this extraordinarily compact memory hicorder close to hand. compact and easy to carry easy, intuitive operation simple pc connection fast, 1ms/second performance despite the compact size built-in, compact-yet-sharp qvga-tft wide lcd easy recording anytime, anywhere! palm-size but powerful
2 high performance instrument that ? ts in your hand ultra compact, yet easy to use actual size when powered on, the settings screen appears along with the waveform monitor, and the new settings navigator blinks. by activating the settings navigator, you can easily navigate by following the simple instructions. soon you will be operating the device like a seasoned professional. real-time waveform monitoring the help text crawls along the bottom of the screen, describing the function of the setting at the blinking cursor. the enhanced waveform monitor window with level meter display facilitates changes to settings by simultaneously displaying real-time input waveforms. the ?settings navigator? function guides operations activate the settings navigator
3 simple, intuitive operation the 8870-20 feels like a hand-held tester, yet takes waveform snapshots. it has no complicated functions - allowing you to observe waveforms quickly and increasing your work eff ciency. n easily make settings while viewing levels on the settings screen. q observe waveforms using only simple memory recorder functions. isolated inputs for safe measurements isolated analog channel inputs provide cat ii overvoltage protection safety for measurements of up to 300 v ac and dc (maximum terminal-to-ground rating). this capability enables safe simultaneous voltage measurements of inverter primary and sec ondar y and stacked bat ter y c ells without damaging the instrument. q 300 v isolation between measurement terminals and hicorder chassis q 300 v isolation between measurement terminals compact, easy-to-carry design volume and weight have both been reduced by 60% from hioki's previously most compact memory hicorder, the 8807-01, to just 40% the volume and 55% the weight. easily pack it in your briefcase to accompany you wherever you go. q only 176 mm wide, 101 mm high and 41 mm thick q weighs only 600 g even with the battery pack installed easy connection to a pc connect to a pc with the supplied usb cable to easily download data that has been automatically saved to a cf card. use the supplied dedicated application program to display and print waveforms on the pc. q easy usb 2.0 data transfer q dedicated application program for displaying and printing waveforms note: the cf card installed in the hicorder appears as a removable disk on the pc, but communication functions such as the capability to change hicorder settings from the pc are not available. floating voltage acquire and store data on a compactflash card for analysis on a personal computer data is simply saved to a cf card. when the hicorder is connected to a pc via usb 2.0, the data is quickly copied from the installed card to the pc: 20,000 waveform screen divisions transfer in about 20 seconds. waveform display and printing, and csv conversion with pc either off-line, or via usb 2.0, easily copy data to a pc. open a data file with the dedicated wave processor (pc application program) for the 8870-20, to import and print waveforms with your own arrow and f gure annotations. of course, screen data can be copied and pasted into common word and excel documents to easily create reports.
4 portable size for on-site jobs catering to a multitude of applications sequential control fault analysis momentary supply dropouts and low ac voltage are often found to be causes of abnormal interruptions and warnings from sequentially controlled devices in factory production and testing lines. for optimal operational analysis, specif y an abnormal power event as a trigger and simultaneously record waveforms of associated sequential relay signals, ac power and dc voltage systems. cb timing measurements analyze the relationships of multi-point logic signals and analog waveforms to detect timing issues that can affect power supply circuit breakers. use logic probes to record relay operations on up to four channels, or use differential probe 9322 for 440-volt power measurements and for support of cat iii and cat iv overvoltage measurement categories. when facility troubles require waveforms right away! battery operation is especially convenient in those situations where no power outlet is available. just plug in the supplied ac adapter to recharge the battery, regardless of whether the hicorder is on or off. the battery pack is automatically quick charged (auto- recharging function) whenever its capacity is depleted. a full charge provides about two hours of operation. synchronize two hicorders together for four-channel recording! for those times when two channels are just not enough, synchronize two 8870-20's using the external trigger i/o terminals (apply the trigger output from one to the external trigger input of the other). then use synchronous start to automatically record four channels of measurement data to a cf card.
5 ?there's a problem with the facility, so you need to see waveforms without full measurement instrumentation?? ? you often have to visit worksites to set up plants and facilities, but typical measurement instruments are too bulky?? record motor inrush current waveforms reliably record waveforms of motor startup current. measure current signals preferably using the 9018-10 clamp-on probe, or with the 3283 clamp on leak hitester. models 3284 and 3285 clamp on ac/dc hitesters are also ideal for dc waveform measurements. con? rm inverter output waveforms inverter performance analysis requires simultaneous observation of the high frequency carrier signal and the low frequency fundamental waveform being switched. the combination of high-speed sampling capability and high-capacity memory make these observations possible. for current waveform observations, use hioki clamp sensors capable of high-frequency measurements without direct electrical contact. capture momentary commercial power outages easily monitor the instantaneous waveform of 50/60 hz commercial power. use triggering to record unexpected waveform anomalies. capture momentary commercial power outages and voltage dips. unattended monitoring for unpredictably intermittent leakage phenomena record instantaneous waveforms of leakage current and line voltage. use out-of-window triggering to detect leakage events only when the input is outside of specif ed upper and lower limits. measurement data is saved to cf card whenever leakage phenomena occur. later, reload the data into the 8870-20 and use the cursor functions to analyze peak current values or breaker tripping events. in the automobile servicing industry analyze phenomena in ways that are just not possible with dedicated fault diagnostic instruments. the high-speed sampling capability of the 8870-20 as a compact hand-held oscilloscope provides mobility in situations that call for delicate testing, such as when performing high-level analysis or measuring specifiable phenomena. long-period recording like a pen recorder record dual-level dc voltage systems as you would with a pen recorder. use the 10 ms sampling rate to record momentary voltage fluctuations.the internal two-megaword memory offers about five hours of recording with a 10 ms sampling interval. fast, 1ms/second performance despite its compact size. isolated inputs ensure safe commercial power measurements. waveform details can be easily observed. have you ever had an experience like these?
6 main unit specifications (accuracy at 23 5c/73 9f, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) analog input (accuracy at 23 5c/73 9f, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) measurement functions number of channels: 2, for voltage measurement input connectors isolated bnc connector (input impedance 1 m , input capacitance 7 pf) max. rated voltage to earth: 300 v ac, dc, cat ii (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) measurement range 10 mv to 50 v/div, 12 ranges, full scale: 10 div, ac voltage for possible measurement/display using voltage axis 1/2: 280 vrms, low-pass filter: 5 hz/50 hz/500 hz/5 khz measurement resolution 1/100 of measurement range (using 12-bit a/d conversion, mea - surement range is 10 times per-division range value) highest sampling rate 1 ms/s (simultaneous sampling in 2 channels) accuracy dc amplitude: 0.5 % of full scale (after zero-adjust, f.s. = 10 div of per-division measurement range) frequency characteristics dc to 50khz - 3db input coupling dc/gnd max. allowable input 400 v dc (the maximum voltage that can be applied across input pins without damage) basic specifcations no. of channels 2 analog and 4 logic channels (standard configuration, logic grounds are common with instrument ground) measurement functions mem (high-speed recording) fastest sampling rate 1 ms/s (1 ms, all channels simultaneously) memory capacity 12 bits 2 mwords/ch removable storage cf card type i slot (standard equipment) 1: up to 1 gb (flash ata) , supports fat16 and fat32 formats backup function clock and settings: 5 years or more (@25c 77f) waveform backup function: available when battery pack 9780 is installed with charge remaining or ac adapter is connected (up to 100 hours with fully charged battery pack). external interface usb: 1 port usb 2.0 high speed mini-b receptacle, transfers files from the installed cf card to a pc when connected (mass storage class device) note: the cf card installed in the hicorder appears as a removable disk on the pc, but communication functions such as the capability to change hicorder settings from the pc are not provided. external control terminals terminal block: external trigger input, trigger output display type 4.3-inch wqvga-tft color lcd (480 272 dots) display resolution waveform section: 20 10 divisions (time axis voltage axis), each division is 20 20 dots environmental conditions (no condensation) temperature and humidity range for use: 0c (32f) to 40c (104f) , 80% rh or less temperature and humidity range for storage: -10c (14f) to 50c (122f) , 80% rh or less compliance standard safety: en61010, emc: en61326, en61000-3-2, en61000-3-3 power requirements ac adapter 9786: 100 to 240 v ac (50/60 hz) battery pack 9780: about 2h continuous operation (ac adapter has priority when both are used) 12 v dc supply: 10 to 16 v (cable available by special order) charging functions the installed battery pack charges when the ac adapter is connected. charging time is about 200 minutes at 25c (77f). notes: charging time depends on battery condition. charging is disabled to protect the battery at ambient temperatures out of 5c (41f) to 30c (86f). power consumption 30 va max. (charging with the ac adapter) 10 va max. (charging with a 12 v supply) dimensions and mass approx. 176 mm (6.93 in) w 101 mm (3.98 in) h 41 mm (1.61 in) d, 600 g (21.2 oz) (with the battery pack 9780 installed) supplied accessories instruction manual 1, measurement guide 1, ac adapter 9786 1, strap 1, usb cable 1, application disk (dedicated program for the 8870-20 ) 1, protection sheet 9809 1 memory recorder functions time axis 100 s to 5 min/div, 20 ranges, time axis resolution 100 points/div, time axis zoom: 2 to 10 in 3 stages, compression: 1/2 to 1/1,000 in 9 stages, auto roll mode display at 50 ms/div or slowely range sampling speed 1/100th of time axis range, (1 s period maximum, simultaneous sampling in all channels) recording length ten settings from 20 to 20,000 div, or continuous (limited by timebase, only the last 20,000 div are saved) pre-trigger records waveforms prior to trigger events, from 0 to 100% of the specified recording length screen types split screen (none, only 1 screen), x-y screen (none, but possible at use with the supplied pc software), waveform or numerical logging (switched), voltage axis zoom (2 to 10), compression (1/2 to 1/5) numerical display instantaneous value or rms value display (only dc and 50/60 hz) reflesh rate: 0.5 sec, sampling speed: 10 ks/sec, 4 digits: (the lowest digit displays as 0 for values 0 to 4, and 5 for values 5 to 9) voltage axis range: 10 mv, 50 mv, 100 mv, 500 mv, 1 v, 5 v, 10 v, 50 v/div, auto ranging, accuracy : 2.5 % of reading 5 digits numerical calculation up to four simultaneous calculations (common to all channels), calculation results are saved to cf card, calculation contents: average, peak, maximum and minimum values, rms, period and frequency calculation range: specified by a/b cursors or whole recording length saving function setting configurations, measurement data (binary and text), screen data (compressed bitmap format), numerical calculation results, thinned data saving (text) cursor readout trace, vertical and horizontal scaling function selectable by model (clamp or differential probe 9322), specified conversion ratio (output ratio, division ratio), 2-point setting method comment entry title comments can be entered for each channel (including logic) screen capture the displayed screen is saved to cf card as a compressed bitmap gauges vertical axis gauges can be displayed for two channels on the waveform screen preserve starting conditions if power fails while measuring, measurement can be automatically resumed when power is restored auto save included scroll bar to jump to a specific waveform location waveform monitor setting is possible while monitoring waveforms on the settings screen logic signal view in 4-bit units, four selectable display positions trigger functions trigger modes single or continuous trigger sources two analog and four logic channels, external trigger (falls below 2.5 v, or shorted terminals) , on/off switching of each source, and/or between sources, manual triggering trigger types (analog) level trigger: triggering occurs when the signal rises or falls through a specified voltage level. window trigger: triggering occurs when the signal level rises above or falls below specified upper and lower limits. voltage drop trigger: intended particularly for 50/60 hz commercial power, triggering occurs when the peak voltage is below the specified value. level setting resolution : 0.5% of full scale (full scale = 10 divisions) logic trigger 1, 0, , or specified pattern trigger filter set by the number of samples, from 0 to 100, in five steps other functions pre-trigger recording to capture waveforms before and after triggering, trigger output (terminal block, 5-volt open-collector active low with at least 1 ms pulse width) time axis sampling period 2m-word (=4mb) 20,000 div max. 100 s/div 1 s 2 s 200 s/div 2 s 4 s 500 s/div 5 s 10 s 1 ms/div 10 s 20 s 2 ms/div 20 s 40 s 5 ms/div 50 s 1 min 40 s 10 ms/div 100 s 3 min 20 s 20 ms/div 200 s 6 min 40 s 50 ms/div 500 s 16 min 40 s 100 ms/div 1 ms 33 min 20 s 200 ms/div 2 ms 1 h 06 min 40 s 500 ms/div 5 ms 2 h 46 min 40 s 1 s/div 10 ms 5 h 33 min 20 s 2 s/div 20 ms 11 h 06 min 40 s 5 s/div 50 ms 1 d 03 h 46 min 40 s 10 s/div 100 ms 2 d 07 h 33 min 20 s 30 s/div 300 ms 6 d 22 h 40 min 00 s 1 min/div 600 ms 13 d 21 h 20 min 00 s 2 min/div 1.2 s 27 d 18 h 40 min 00 s 5 min/div 3.0 s 69 d 10 h 40 min 00 s ? because data is not recorded directly to the cf card, maximum recording time is independent of cf card capacity. maximum recording time is determined only by internal memory capacity. ? operation cannot be guaranteed when recording continuously for more than one year (with a slow timebase). ? maximum recording length is the same whether using one or two channels.
7 wave processor program for the 8870 -20 supported measurement instruments memory hicorder 8870-20 only operating environment pc running windows 2000, xp, or vista (32-bit versions) file loading loadable data format: memory function data (mem extension) max. loadable file size: the maximum size that can be stored by the 8870-20 (subject to the capacity of the pcs operating environment) overwriting save overwrites saved scaling and title/channel comments slideshow display sequentially displays waveform files in the same folder text conversion data conversion format: select from csv, tab-separated or space- separated object data range: whole range, or between cursors data thinning: available by specifying interval conversion methods: analog waveform data to voltage values, logic data is converted to ones and zeros conversion channels: selectable header contents: title, trigger date, timebase, comments, per-channel setting conditions batch conversion: specify multiple files for batch conversion displaying display language: english or japanese (select during installation) waveform display: scroll and magnify/reduce the time axis of the displayed waveform data image, move the zero position of each channel, zoom and set the vertical axis of each channel independently (variable gain) numerical value display: included cursor functions: manipulate a and b cursors independently, and display time and voltage numerically. max. displayable channels: two analog and four logic channels gauge display: time gauge (absolute or relative time, seconds, data points), voltage gauge (for each channel) figure annotations: text boxes, straight lines, arrows, circles and rectangles at any location screen capture: extended meta format, bitmap format search functions: date, maximum, minimum, level and window search template function: save and reload waveform file display configurations printing printer support: color and monochrome printing on printers supported by the operating system printable ranges: all data, screen capture and specifiable areas print formats: undivided, two divisions, 2, 4, 8 or 16 traces, single xy screen, gauges, channel comments, zero-position comments, and a/ b cursor values print preview and waveform screen hard copy/logging print functions are included l designed especially for memory hicorder 8870-20 application program displays and prints waveforms, and converts measurement data to csv text fles on a windows pc. l provides x-y display capability not available on the hicorder l generate reports using templates, with fgure annotations and entered comments options specifications (sold separately) cable length and mass: main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz) differential probe 9322 (accuracy at 23 5c/73 9f, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) function for high-voltage floating measurement, power line surge noise detection, rms rectified output measurement dc mode for waveform monitor output, frequency characteristics: dc to 10 mhz ( 3 db), amplitude accuracy: 1 % of full scale (at max. 1000 v dc), 3 % of full scale (at max. 2000 v dc) (full scale: 2000 v dc) ac mode for detection of power line surge noise, frequency characteristics: 1 khz to 10 mhz 3 db rms mode dc/ac voltage rms output detection, frequency characteristics: dc, 40 hz to 100 khz, response speed: 200 ms or less (400 v ac), accuracy: 1 % of full scale (dc, 40 hz to 1 khz), 4 % of full scale (1 khz to 100 khz) (full scale: 1000 v ac) input input type: balanced differential input, input impedance/ capacitance: h-l 9 m /10 pf, h/l-unit 4.5 m /20 pf, max. rated voltage to earth: when using grabber clip 1500 v ac/dc (cat ii ), 600 v ac/dc (cat iii), when using alligator clip: 1000 v ac/dc (cat ii), 600 v ac/dc (cat iii) maximum allowable input 2000 v dc, 1000 v ac (cat ii), 600 v ac/dc (cat iii) output voltage divider for 1/1000 of input, bnc connectors (output switchable for 3 modes dc, ac, rms) power source connect the ac adapter 9418-15 , (power cannot be supplied from the logic terminals of the 8870-20) logic probe 9320 -01 (accuracy at 23 5c/73 9f, 35 to 80% rh; accuracy guaranteed for 1 year) function detection of voltage signal or relay contact signal for high/low state recording input 4 channels (common ground between unit and channels), digital/ contact input, switchable (contact input can detect open-collector signals), input impedance: 1 m (with digital input, 0 to + 5 v), 500 k or more (with digital input, + 5 to + 50 v), pull-up resistance: 2 k (contact input: internally pulled up to + 5 v) digital input threshold 1.4 v/2.5 v/4.0 v contact input detection resistance 1.5 k or higher (open) and 500 or lower (short), 3.5 k or higher (open) and 1.5 k or lower (short), 25 k or higher (open) and 8 k or lower (short) response speed 500 ns or lower max. allowable input 0 to + 50 v dc (the maximum voltage that can be applied across input pins without damage) cable length and mass: main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) note: the unit-side plug of the 9320-01 9320 logic probe 9321 -01 (accuracy at 23 5c/73 9f, 35 to 80% rh; accuracy guaranteed for 1 year) function detection of ac or dc relay drive signal for high/low state recording. can also be used for power line interruption detection input 4 channels (isolated between unit and channels), high/low range switching, input impedance: 100 k or higher (high range), 30 k or higher (low range) output (h) detection 170 to 250 v ac, dc (70 to 250 v ) (high range) 60 to 150 v ac, dc (20 to 150 v) (low range) output (l) detection 0 to 30 v ac, dc (0 to 43 v) (high range) 0 to 10 v ac, dc (0 to 15 v) (low range) response time rising edge 1 ms max., falling edge 3 ms max. (with high range at 200 v dc, low range at 100 v dc) maximum allowable input voltage 250 vrms (high range), 150 vrms (low range) (the maximum voltage that can be applied across input pins without damage) cable length and mass: main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) note: the unit-side plug of the 9321-01 9321 l multiple fles can be batch-converted to csv data
head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@hiokiusa.com distributed by all information correct as of may 22, 2008. all speci? cations are subject to change without notice. 8870-20e1-85m-05p printed in japan hioki (shanghai) sales & trading co., ltd. : 1904 shanghai times square of? ce, 93 huai hai zhong road shanghai, p.r.china postcode: 200021 tel +86-21-6391-0090/0092 fax +86-21-6391-0360 e-mail: info-sh@hioki.cn beijing off ce : a-2602 freetown, 58 dong san huan nan road beijing, p.r.china postcode: 100022 tel +86-10-5867-4080/4081 fax +86-10-5867-4090 e-mail: info-bj@hioki.cn guangzhou off ce : room 303, pro? t plaza, no.76, west huangpu road guangzhou, p.r.china postcode: 510623 tel +86-20-38392673/2676 fax +86-20-38392679 e-mail: info-gz@hioki.cn 8 memory hicorder 8870 -20 (english model, instrument only) note: test leads are not included. purchase the leads appropriate for your application separately. ac adapter 9786 is the only supplied accessory. removable storage supplied with pc card adapter pc card 128m 9726 (128mb capacity) pc card 256m 9727 (256mb capacity) pc card 512m 9728 (512mb capacity) pc card 1g 9729 (1gb capacity) pc card precaution u s e o n l y p c c a r d s s o l d by hioki . c o m p a t i b i l i t y a n d p e r f o r m a n c e a re n o t guaranteed for pc cards made by other manufacturers. you may be unable to read from or save data to such cards. clamp on ac/dc hitester 3284 20 a to 200 a ac/dc clamp on ac/dc hitester 3285 200 a to 2000 a ac/dc conversion adapter 9199 female banana terminals to bnc plug (output) output cord 9094 3.5-mm mini plug, and banana plugs, 1.5 m (4.92 ft) length not ce marked ac adapter 9445 -02/-03 for the 3283/3284/3285, 9v/1a clamp tester connection requires output cord 9094 and conversion adapter 9199 . clamp on probe 9132 -10 20 a to 1000 a not ce marked clamp on leak hitester 3283 10 ma to 200 a ac clamp on probe 9018 -50 10 a to 500 a current measurement supplied ac adapter voltage measurement (requiring power for probe) ac adapter 9418 -15 for powering differential probe 9322 , 100 to 240 v ac, 12 v/2.5 a options for voltage measurement (not supplied. purchase together with attachment clips appropriate for your application.) case carrying case 9782 includes compartment for options, resin coated case soft case 9812 includes space for small items, neoprene rubber voltage measurement connection cord 9198 cat ii-300 v, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length connection cord 9197 cat ii-500 v, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length connection cord 9790 (thin type) cat ii 300v, ultra- flexible 2.8 mm (0.11 in) diameter test lead cable, 1.5 m (4.92 ft) length note: attachment clips sold separately. alligator clip 9790 -01 red/black set attaches to the ends of test leads (9790) grabber clip 9790 -02 red/black set attaches to the ends of test leads (9790) contact pin 9790 -03 red/black set attaches to the ends of test leads (9790) logic signal measurement (one probe can be installed to provide four channels) logic probe 9320 -01 4-channel type, for voltage/contact signal on/off detection (miniature terminal type) logic probe 9321 -01 4 isolated channels, on/off detection of ac/dc voltage (miniature terminal type) conversion cable 9323 used for connecting the 9320/9321 and 8870 series memory hicorders, because the terminal shapes are different. * this cable is not required for the smallterminal types 9320-01 and 9321-01. battery pack 9780 nimh, charges while installed battery pack charges while installed in the hicorder supplied accessories protection sheet 9809 for lcd protection, pairs of additional sheets can be purchased separately. ac adapter 9786 100 to 240 v ac differential probe 9322 2 kv dc for input up to 1 kv ac, cat iii-600 v and cat ii-1000 v maximum terminal-to-ground rating tip expanders attachment clips are sold separately from connection cord 9790. purchase the appropriate attachment clips for your application separately tip expanders 9790 -01 tip expanders 9790 -03 tip expanders 9790 -02